TM 9-2320-279-20-3
M978 Tanker Maintenance Instructions (Cont)
a. Removal.
(1)
Remove two locknuts (1) and
U-bolt (2) from bracket (3).
WARNING
Contact with fuel can irritate eyes
and skin. Do not let fuel get into
eyes. If fuel comes into contact
with eyes, immediately rinse eyes
with clear water. Wash fuel off skin
with soap and water as soon as
possible after contact.
(2)
Remove flow limiting valve (4)
from grating (5) and drain fuel.
b.
c.
Installation.
(1)
Position flow limiting valve (4)
against bracket (3) on grating (5).
(2)
Install flow limiting valve (4)
with U-bolt (2) and two
locknuts (1).
Follow-on Maintenance.
(1)
Install V5 air actuated flow valve
(para 25-19).
(2)
Install flow limiting valve to filter-separator piping (para 25-11).
(3)
Install filter-separator (para 23-4).
(4)
Install V18 BULK DELIVERY VALVE (para 25-31).
.
(5)
Perform unfiltered bulk unloading (TM 9-2320-279-10).
(6)
Check flow limiting valve for leaks.
END OF TASK
25-151