TM 9-2320-279-34- 1
Electrical System Maintenance Instructions (Cont)
6-11. JUNCTION BOX AND CONNECTOR REMOVAL/REPAIR/INSTALLATION (M977, M985 )
(CONT).
b.
Disassembly .
(1)
Remove cap (1).
(2)
Remove four screws (2),
lockwashers (3), washers (4), and
cover (5) from box (6).
NOT E
Tag and mark wires before removing or
disconnecting.
(3)
Remove two screws (7) and three
wires (8).
(4)
Remove sealnut (9), lockwasher (10),
switch (11), and nut (12).
NOT E
Connector must be removed
with cable module.
(5)
Remove nut (13) and
lockwasher (14).
(6)
Remove nut (15),
lockwasher (16), and
connector (17).
6-58