TM-9-2320-280-20-1

TRUCK, UTILITY: M998 SERIES

TECHNICAL MANUAL; UNIT MAINTENANCE; VOLUME 1 OF 3

JANUARY 1996

  TM-9-2320-280-20-1 - Page 115 of 888

Table 2-1. Unit Level Preventive Maintenance Checks and Services HMMWV (Cont'd)
I T E M
N O .
I N T E RVA L
ITEM TO BE
I N S P E C T E D
P R O C E D U R E S
24
Semi-
Ambulance
a.
Check DC outlets for proper oper-
a.
No DC voltage at
Annual
( M 9 9 6
,
tion. Using multimeter, check for volt-
outlet, or not within
M996A1,
age at DC receptacles. If engine is run-
range.
M997,
ning, voltage should be 27-28 volts. If
M997A1, and engine is not running, voltage should
M997A2)
be 24.2-25.2 volts. Reefer to para. 2-39,
electrical troubleshooting, if voltage
is not within the specified range.
b.
Inspect and tighten two mounting
b.
Body not securely
capscrews securing ambulance body to
mounted to floor.
cargo floor to 90 lb-ft (122 N
m).
Tighten seven capscrews securing
ambulance body to “D” beam to
90 lb-ft (122 N
m).
c.
(M997, M997A1, and M997A2 only)
c
. Any class III leak.
Inspect compressor for security of
mounting and oil leakage.
25
Semi-
DeepWater
a.
Inspect vent tubes for bends,
Annual
Fording Kit
cracks, breaks, deterioration, and
restrictions.
b.
Inspect vent tube mounting hard-
ware for proper installation.
c.
Inspect intake and exhaust exten-
c.
Any exhaust extension
sions for proper installation and leaks.
leaks.
TM 9-2320-280-20-1
2 - 2 4
Change 1
NOT FULLY MISSION
C A PABLE IF:


Back to Top