TM 9-2320-280-20-1
REFERENCE INFORMATION
ALTERNATOR
2-221
1. Connect RED clip to the indicated
test point, BLACK clip to negative or
ground.
2. Start Test 89, DC Volts.
3. Displayed reading is in volts.
1. Slide boot back from wire lug to expose
red terminal.
2. Make contact at stud.
0-45 DC VOLTS
STE/ICE-R TEST 89
1. Start Test 10, Engine RPM.
2. Crank or start the engine. Displayed
reading is RPM. Set engine to fast
idle of 1200 - 1500 RPM.
ENGINE RPM
STE/ICE-R TEST 10
1. Connect probe.
2. Start Test 90, DC amps.
3. Displayed reading is in amps.
0-1500 AMPS DC
STE/ICE-R TEST 90