Section II. ILLUSTRATED MANUFACTURING INSTRUCTIONS (Cont'd)
WINCH BATTERY CABLE
CABLE
CUT
ITEM
PART
LENGTH
MANUFACTURED
END TERMINALS
END INSULATOR
NO.
NUMBER
(INCHES)
FROM NSN
NSN
1
15847
74
M23053/03-0
(81349)
2
15848
87-1/2
M23053/03-0
(81349)
INSTRUCTIONS:
1. Determine cable number needed from RPSTL and cut cable 6145-00-538-8219 to length as shown.
2. Select and solder proper end terminals to cable ends as shown. (Refer to TC 9-237 for soldering
instructions.)
3. Install insulator as shown.
4. Cut 14 inches of spiral wrap from bulk 25 FT 2661-8P (98441) and install as shown. Spiral wrap is
held in position with black tape at both ends.
5. Mark and install identification band using old cable as reference.
Figure D-38. Winch Battery Cable
MATERIAL BLOCK
STOCK SIZE
DESCRIPTION
SPECIFICATION
4 IN. GAGE, TYPE 1, CLASS A
WIRE, ELECTRICAL
MIL-C-13486
2 ± 0.25 IN.
12 ± 0.25 IN.
14 ± 0.25 IN.
INSULATOR
IDENTIFICATION BAND
SPIRAL WRAP
BLACK TAPE
TERMINAL
TERMINAL


Back to Top