TM-9-2320-280-34

TRUCK, UTILITY: M998 SERIES

TECHNICAL MANUAL; DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE

JANUARY 1996

  TM-9-2320-280-34 - Page 1067 of 1258

TM 9-2320-280-34
2 2 -1 6 . 1 4
Change 1
2 2 - 9 . 2 .
LEFT FRONT FLOOR PANEL REPAIR (Co n
t ’ d)
3.
Apply approximately 0.125-in. thickness of adhesive sealant to shaded mating surface of insert
panel (1) and metal strip D (2).
4.
Position metal strip D (2) on insert panel (1) and install with seven rivets (3).
5.
Remove any adhesive residue and clean edges of metal strip D (2) and insert panel (1).
1.
Position metal strip B (6), with arrow facing up and toward metal strip C (5), on insert
panel (1). Align reference line (4) with edge of metal strip B (6).
2.
Using metal strip B (6) as a template, locate, mark, and drill twelve 0.187-in. diameter holes
through insert panel (1).
3.
Apply approximately 0.125-in. thickness of adhesive sealant to shaded surface of insert panel (1)
and metal strip B (6).
g. Metal Strip B and Insert Panel Assembly