TM 9-2320-283-20-1
PRINCIPLES OF OPERATION.
1-21.
AUXILIARY AIR-POWERED SYSTEMS.
c.
Fan Clutch Controls
FAN CLUTCH.
When actuator opens, compressed air from primary reservoir engages clutch to actuate fan.
FAN CLUTCH ACTUATOR.
Opens air connection between primary reservoir and fan clutch when coolant temperature
rises above 190°F.
PRIMARY RESERVOIR.
Supplies air pressure to engage clutch and rotate fan when actuator opens air connection.
TA 236801