TM 9-2320-283-20-1
Table 2-1.
Unit Level Preventive Maintenance Checks and Services M915A1
Procedures:
Item
Item to be
Not Mission
No.
Interval
Inspected
Capable If:
29
Semi-
Rear
Axle Housing Vent Plug
Annual
Axle
b.
Remove vent plug from axle
b.
Axle vent
Spring
housing.
Wash vent plug in sol-
plug missing or
and
vent and allow to air dry.
cannot be
Walking
cleaned.
Beam
c.
Coat
threads with pipe
thread sealing compound and in-
Continued
stall axle housing breather.
30
Semi-
Front
NOTE
Annual
Axles
COLD TEMPERATURE OPERATION
For operating of equipment in
expected continuous tempera-
tures below 0°F (-18° C), remove
lubricants prescribed in the key
for temperatures above 0° F (-18°
C).
Re-lubricate with lubri-
cants specified in the key for
temperatures 0° F to -50° F (-18°
C to -46° C).
NOTE
Pressure gun should be held on
fittings until new grease ap-
pears.
This will assure that
all the old contaminated grease
has been forced out.
Drag
Lubricate drag link with GAA.
Fitting will
Link
not purge old
lubricant out
of component.
Change 1
2-21