TM 9-2320-283-20-1
TROUBLESHOOTING.
2-11.
TROUBLESHOOTING PROCEDURES (Continued).
MALFUNCTION
INSTRUCTION
INDICATION
YES
NO
31.
INSTRUMENT PANEL GAGES NOT WORKING (Continued).
NOTE
• Determine which gage is not working by visual inspection, then go to the
proper step as listed below.
• If water temperature gage is not working, do step 8.
• If fuel gage is not working, do step 9.
• If voltmeter is not working, do step 10.
• If transmission oil temperature gage is not working, do step 11.
• If engine oil pressure gage is not working, do step 12.
8.
Check water temperature
gage:
a.
With a jumper wire,
Gage
Go to step b.
Replace gage
momentarily ground
operates.
(para 3-73).
circuit 55D-RD
terminal of water
temperature gage.
b.
With a jumper wire
Gage
Replace sending
Repair circuit
momentarily ground
operates.
unit (para
55D-RD and/or
circuit 55E-RD
3-101).
55D-RD (para
terminal of water
3-127).
temperature sending
unit.
2-92