TM-9-2320-283-20-2

TRUCK TRACTOR, LINE HAUL, 50,000 GVWR, 6X4, M915A1

TECHNICAL MANUAL; ORGANIZATIONAL MAINTENANCE PART 2 OF 3

DECEMBER 1983

  TM-9-2320-283-20-2 - Page 418 of 852

TM 9-2320-283-20-2
ELECTRICAL SYSTEM.
3-132. UTILITY OUTLET RECEPTACLE REPLACEMENT (Continued).
LOCATION / ITEM
ACTION
REMARKS
NOTE
Replacement
of
utility
outlet
receptacles is the same for both
sides.
A.
REMOVAL.
1.
Two rivets (4).
Remove from item (3) and
Use a drill and drill
item (6).
motor.
2.
Cover (5).
Remove from item (3).
3.
Inlet (3).
Pull away from cab.
4.
Two screws (1),
Remove from item (3).
terminal (2), and
terminal (7).
B.
INSTALLATION.
5.
Terminal (2),
Install on item (3).
Terminal (2) should go
terminal (7), and
to gold colored contact.
two screws (1).
6.
Coyer (5).
Install in item (3).
7.
Inlet (3).
Put in place in cab.
8.
Two new rivets
Secure item (3) and item
(4).
(6) to cab.
NOTE
Follow-on maintenance action required:
None.
3-790