TM 9-2320-285-10
2-14.
OPERATING PROCEDURES (Continued)
g.
tilting Cab 45 degrees (continued).
(3)
Remove pump handle from brackets at left rear inside corner of cab.
(4)
Insert pump handle in cab tilt pump and rotate control valve clockwise until control valve is against stop.
WARNING
Stay out from under cab unless safety bar is supporting full weight of cab.
Failure to follow this procedure
could result in severe injury from falling cab.
(5)
Move pump handle up and down to raise cab until safety bar drops into first notch.
Do not attempt to jack
cab past safety bar stop bolt.
2-45