TM-9-2320-285-24-1

TRUCK TRACTOR, YARD TYPE, 43,500 LB GVW, DED, 4X2, ARMY MODEL M878A1

TECHNICAL MANUAL; ORGANIZATIONAL, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL

OCTOBER 1985

  TM-9-2320-285-24-1 - Page 406 of 987

TM 9-2320-285-24-1
2-34.
BATTERY SYSTEM MAINTENANCE
a.
Battery Cables and Batteries (cont).
STEP
LOCATION
ITEM
ACTION
REMARKS
BATTERY CHARGING (cont)
15
NOTE
(cont)
Make certain battery cell covers are installed before proceeding.
b.
Battery charger
Turn on
c.
Battery cell
a. Remove
Remove cell covers periodic-
covers
ally and check specific
gravity (step 9b) and
electrolyte level.
Add
distilled water to maintain
level 3/8 inch above plates
b. Install
16
Batteries
a.
Specific
Check
Check after two hours of
(15)
gravity
battery charging.
Use
hydrometer.
Battery is
considered fully charged
when the specific gravity
does not change.
If one or
more cells of the battery
has a specific gravity less
than 1.230 after prolonged
charging,
the battery is
defective and must be
replaced
b.
Battery charger
Turn off
Disconnect leads
c.
Battery box lid
Close and
Para 2-34b
secure
2-383