  TM-9-2320-328-13-P-1 - Page 680 of 1318

TM 9-2320-328-13&P-1
0072-16
DRAFT
0072
Change 1
..
HWT2629
..
Step 21.
Turn ENGINE switch to OFF position (TM 9-2320-422-10).
Pull battery disconnect
switch to off position (WP 0007).
Disconnect pump operator’s panel wire harness
pressure governor control connector (WP 0216).
Disconnect main wire harness cab
pressure governor control connector (WP 0197).
With a test lead set, check for
continuity across CAT Hi wire (yellow) from main wire harness cab pressure governor
control connector, terminal 8 to pump operator’s panel wire harness pressure governor
control connector, terminal 8.
..
If there is continuity, go to Step 26.
..
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION