TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 1203 of 1390

TM 9-2320-328-13&P-2
0302-25
DRAFT
0302
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
33. Install pressure governor ECU service connector (65) on bracket (67) with four screws (66), lockwashers (63),
washers (64), and locknuts (62).
34. Connect pump hose wire harness connector (60) on chassis datalink Y connector (61).
35. Connect pump house wire harness connector (58) on pressure governor control ECU datalink Y
connector (59).
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
36. Install wire 2774 (56) on primer pump solenoid (57) with locknut (55).
HWT2244A
HWT2243


Back to Top