TM-9-2320-328-13-P-2

HEMTT-BASED WATER TENDER (HEWATT)

TECHNICAL MANUAL; OPERATOR’S AND FIELD LEVEL MAINTENANCE MANUAL (INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST); PART 2 OF 3

MARCH 2009

  TM-9-2320-328-13-P-2 - Page 265 of 1390

TM 9-2320-328-13&P-2
0129-11
DRAFT
0129
Change 1
HWT2432
f.
Check if WATER TANK fill tower and cover
operate and are free from damage and loose
or missing hardware.
Check water tank for
contamination or debris.
(Lubricate if required, refer to Table 2.)
g.
Check if FOAM TANK fill tower and cover
operate and are free from damage and loose
or missing hardware,
Check foam tank for
contamination or debris.
(Lubricate if required, refer to Table 2.)
h.
Check walkway grating for damage or loose or
missing hardware.
i.
Check if warning light bezel boxes are free
from damage and loose or missing hardware.
j.
Check hydraulic oil reservoir oil level.
If arrow
is in green section, hydraulic oil level is ok.
(Fill if required, refer to Table 2.)
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
If hydraulic oil
level is low.
If
hydraulic oil
appears milky or
foaming.
Table 1.
Preventive Maintenance Checks and Services. (Continued)
Item
No.
Interval
Item To Inspect
Or Service
Procedure
Not Fully Mission
Capable if:


Back to Top