CONDITION/INDICATION
Is hydraulic fluid at normal operating temperature after cycling mast control down?
DECISION
No - Notify Supervisor.
Yes - Test 5 - Does hoist operate normally?
TEST 5 - Does hoist operate normally?
1.
If stowed, raise crane to operating position. (WP 0038)
2.
Operate hoist. (WP 0038)
Figure 5.
CONDITION/INDICATION
Does hoist operate normally?
DECISION
No - Notify supervisor.
Yes - Problem corrected.
END OF WORK PACKAGE
TM 9-2320-343-10
0124
0124-6