OPERATOR MAINTENANCE
MAST RAISES OR LOWERS SLOWLY
INITIAL SETUP:
Equipment Condition
Vehicle setup for crane operations.
(WP 0038)
TROUBLESHOOTING PROCEDURE
MAST RAISES OR LOWERS SLOWLY
TEST 1 - Does mast raise and lower normally after running engine for 20 minutes with
PTO engaged?
NOTE
Common problems that crane operators may see are:
1.
Slow or abnormal operation.
2.
Crane will not pick up load.
Common causes of problems are:
1.
Cold hydraulic fluid (slow operation).
2.
Low engine speed (slow or abnormal operation).
3.
Operating two craning functions at the same time (slow operation).
4.
Load too heavy (crane will not pick up load).
5.
Air in cylinder or hoist motor (abnormal operation).
Report all problems to organizational maintenance.
If outside temperature is 0°F (-17°C), hydraulic fluid may not flow easily.
1.
If loaded, set load down (WP 0038) and disconnect load hook.
2.
Operate engine (WP 0044) for 20 minutes with HYD ENABLE switch set to ON to bring
hydraulic fluid up to operating temperature.