Table 1.
PMCS - WEEKLY - Continued
Item
No.
Interval
Item to
be
Checked
or
Serviced
Procedure
Equipment
Not Ready/
Available If:
b.
Check fan control.
c.
Check cabin air directional
control.
d.
Check heater temperature
control.
e.
Check air conditioning con-
trol.
29
Weekly
Material
Handling
Crane
1.
Inspect crane for loose nuts and
bolts, hydraulic leaks, damage to
hydraulic hoses and lines, and
obvious damage.
Class III
leak present
or damage
to hoses,
lines, or fit-
tings.
NOTE
For more information on ma-
terial handling crane operat-
ing instructions, refer to grove
crane operation (manual con-
trol) procedures. (WP 0038)
2.
Check that crane hydraulic sys-
tem is operable as follows:
a.
Start engine. (WP 0044)
b.
Set HYD ENABLE switch in
on position. MAIN HYD EN-
ABLE indicator will illumi-
nate.