Table 1.
HIAB Crane Front Remote Station And Remote-Control System Controls
And Indicators. - Continued
Key
Control/
Indicator
Function
9
Outer Boom
Control Switch
Lever
Raises and lowers outer boom.
10
HOIST Control
Switch Lever
Raises and lowers load.
11
BOOM Exten-
sion Control
Switch Lever
Extends and retracts boom second stage.
12
Remote-Con-
trol Power
Switch
Turns electrical power ON/OFF to HIAB crane solenoid valve.
This switch is also used for emergency shutdown of the crane.
13
Remote-Con-
trol Receptacle
Remote-control cable connection point.
14
Remote-Con-
trol Cable
Connects portable remote-control unit to either front remote
station or rear junction box.
15
Power Display
Box
Supplies electrical power to all other units of crane system
and displays crane performance data for operator.
16
Power Button
Press button to turn electrical power to crane on and off. Front
remote station will not operate without this button energized
(turned on).
TM 9-2320-344-10
0027
0027-4