TM-9-2320-346-10

TRUCK, COMMON BRIDGE TRANSPORT (CBT), 8X8 M1977A4 W/WINCH AND M1977A4 W/O WINCH

TECHNICAL MANUAL; OPERATOR'S MANUAL

OCTOBER 2008

  TM-9-2320-346-10 - Page 807 of 1184

AIR RESERVOIR
DRAIN MANIFOLD
AIR RESERVOIR NO. 3
DRAIN VALVE
AIR RESERVOIR NO. 2
DRAIN VALVE
AIR RESERVOIR NO. 4
DRAIN VALVE
AIR RESERVOIR NO. 5
DRAIN VALVE
AIR RESERVOIR NO. 1
DRAIN VALVE
Figure 2.
CONDITION/INDICATION
Are any petcock valves open?
DECISION
Petcock(s) open - Test 6 - Does buzzer stop, and air indicator light extinguish?
Petcock's closed - Test 3 - Is trailer air supply control in correct position?
TEST 3 - Is trailer air supply control in correct position?
1.
Check that trailer air supply control is pulled out (OFF position) if no trailer is coupled,
and pushed in (ON position) if trailer is coupled.
2.
If trailer air control is found in an incorrect position, set to correct position.
TM 9-2320-346-10
0117
0117-3


Back to Top