Table 2-4. Electrical Troubleshooting (Contd).
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
28. TURN SIGNALS OPERATE INCORRECTLY WITH TURN SIGNAL CONTROL LEVER IN ONE OR MORE
POSITIONS
Test turn signal control unit continuity.
Step 1. Place battery switch to OFF position.
Step 2. Remove harness connector from turn signal switch.
Step 3. Remove indicator lamp from turn signal switch (para. 4-19).
Step 4. Set multimeter to RX1 scale.
Step 5. If any circuit does not test as shown in chart 1 below, replace turn signal switch
(para. 4-19).
2-119