TM 9-2320-361-24-1
0023 00
0023 00-8
PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) (Contd)
Table 1. Preventive Maintenance Checks and Services (PMCS) (Contd).
ITEM
NO.
INTERVAL
ITEM TO CHECK/
SERVICE
PROCEDURE
EQUIPMENT NOT
READY/AVAILABLE IF:
17
18
Semiannually
Semiannually
Semiannually
Vibration
damper
Engine
crankcase
breather
adapter
a.
Make sure inner member and outer
member alignment marks are aligned.
If not, replace vibration damper
(WP 0028 00).
WARNING
Stay clear of moving parts. Failure to do
so may result in injury or death to
personnel.
b.
With engine running and at idle
(TM 9-2320-361-10), visually inspect
vibration damper (1) for wobble and
runout. If wobble or runout exist,
replace vibration damper (WP 0028 00).
Remove engine crankcase breather
adapter (3) and inspect. Clean as
necessary (WP 0045 00).
1