PERSONNEL HEATER FUEL LINE AND BLOWER HOUSING REPLACEMENT (Contd)
REMOVAL
1.
Loosen nut (3) and remove fuel line (4) from fuel control valve (1).
2.
Loosen nut (5) and remove fuel line (4) from burner fuel inlet (6).
3.
Remove blower housing (2) from heat exchanger (7) and heater housing (8).
INSTALLATION
1.
Place blower housing (2) in heater housing (8).
2.
Install fuel line (4) on burner fuel inlet (6) through blower housing (2).
3.
Install fuel line (4) on fuel control valve (1).
4.
Install personnel heater igniter (WP 0429 00).
5.
Connect battery ground cable (WP 0126 00).
6.
Release parking brake and remove wheel chocks (TM 9-2320-361-10).
END OF WORK PACKAGE