TM-9-2320-362-14-P

TRUCK UTILITY: S250 SHELTER CARRIER, 4X4, M1037 FOR TRAFFIC JAM AN/TLQ-17A(V)3 (HMMWV)

TECHNICAL MANUAL; OPERATOR, UNIT, DIRECT SUPPORT AND GENERAL SUPPORT MAINTENANCE MANUAL INCLUDING REPAIR PARTS AND SPECIAL TOOLS LIST FOR ELECTRICAL ENVIRONMENTAL SYSTEM (EES)

APRIL 1992

  TM-9-2320-362-14-P - Page 35 of 353

TM 9-2320-362-14&P
Table 3-1.
Unit Preventive Maintenance Checks and Services (Cont’d)
S-Semiannually
A-Annually
B-Biennially
ITEM
INTERVAL
ITEM TO BE
NO.
INSPECTED
PROCEDURES
s
A
B
1
POWER INTERFACE
a. Inspect power cable connections
BOX (Cent’d)
for tightness. Tighten loose
connections.
b. Inspect terminals and power
cables for corrosion, dirt, grease,
or fungus.
Clean with wire brush,
wiping rags, and detergent.
c. Inspect power cables for frayed,
cracked, or worn insulation.
Repair
or replace damaged components.
Install fixed rear door (4) against
side of truck (3) and secure with
captive screw (1) and four special
bolts (5).
2
COMPRESSOR
Inspect compressor for secure
mounting and oil leakage.
Tighten
any loose mounting hardware
(TM 9-2320-280-20), and report any
oil leakage to DS maintenance.
3
200 AMP
a. Inspect 200 amp alternator and
ALTERNATOR
voltage regulator for proper
installation and mounting.
b. Inspect electrical wiring for
broken strands, frayed, cracked, or
worn insulation, and loose
connections.
3-5


Back to Top