e87.
11K SELF-RECOVERY WINCH DOES NOT PAY OUT
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-365-10).
Personnel Required
(2)
References
TM 9-4910-571-12&P
Tools and Special Tools
Tool Kit, Genl Mech (Item 44, Appendix C)
STE/ICE-R (Item 39, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
Wrench, Torque, 0-200 lb-in. (Item 58, Appendix C)
Materials/Parts
Wire, Elect, 50 ft (Item 77, Appendix D)
KNOWN INFO
1.
Is 24 VDC present on winch
out solenoid L5 connector
terminal 1?
WARNING
Read WARNING
on following page.
START
YES
NO
Go to step 3 of this fault.
TEST OPTIONS
Voltage Test or
STE/ICE-R Test #89
REASON FOR QUESTION
This question eliminates
possible problems and
determines where
troubleshooting continues.
TM 9-2320-365-20-1
2-958
Change 2
Circuit breaker OK.
11K self-recovery winch reels
in OK.
POSSIBLE PROBLEMS
Faulty winch control valve
cable assembly.
Faulty winch control valve
assembly.
Faulty WINCH IN/OUT switch.
Faulty PTO cable assembly.
Faulty auxiliary panel cable
assembly.