CONTINUITY TEST
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J7-1.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 1426
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10).
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J7-2.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 1408
(para 2-40) or replace WTEC II dashboard
cable assembly (para 7-10).