TM-9-2320-365-20-1

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 1 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-1 - Page 265 of 1760

VOLTAGE TEST
WARNING
Remove rings, bracelets, watches, necklaces,
and any other jewelry before working around
vehicle.
Jewelry can catch on equipment and
cause injury or short across electrical circuits
and cause severe burns or electrical shock.
(1) Set multimeter to volts DC.
(2) Connect positive (+) probe of multimeter to
terminal lug TL33.
(3) Connect negative (-) probe of multimeter to
ground.
(4) Lower cab (TM 9-2320-365-10).
(5) Position master power switch to on
(TM 9-2320-365-10).
(6) Press starter pushbutton
(TM 9-2320-365-10) and note reading on
multimeter.
(7) If 24 VDC is not present, go to step 9 of
this fault.
(8) Position master power switch to off
(TM 9-2320-365-10).
(9) Raise cab (TM 9-2320-365-10).
Change 1
2-163
TM 9-2320-365-20-1


Back to Top