CONTINUITY TEST
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector PX7-17.
(3)
Connect negative (-) probe of multimeter to
ground and note reading on multimeter.
(4)
If continuity is not present, repair wire 3030
(para 2-40) or replace WTEC II dashboard cable
assembly (para 7-10) or WTEC III dashboard
cable assembly (para 7-11).
(1)
Remove PDP cover (para 16-2).
(2)
Remove relay K52 from PDP.
(3)
Set multimeter to ohms.
(4)
Connect positive (+) probe of multimeter to
relay K52 terminal 30.
(5)
Connect negative (-) probe of multimeter to
relay K52 terminal 87A and note reading on
multimeter.
(6)
If continuity is not present, replace relay K52
(para 7-9).