PRESSURE TEST
(1)
Position drain pan under air/hydraulic
manifold.
(2)
Disconnect hydraulic hose 514 from
port T1.
(3)
Connect STE/ICE-R between hydraulic
hose 514 and port T1.
(4)
Start engine (TM 9-2320-365-10).
(5)
Position SUSPENSION knob to LOWER
(TM 9-2320-365-10).
(6)
Position FUNCTION SELECT knob to
SUSPENSION (TM 9-2320-365-10).
(7)
Push and hold PUMP plunger button
(TM 9-2320-365-10) and perform
STE/ICE-R Test #51.
(8)
If 2,500-4,000 psi (17,238-27,580 kPa) is
not present, replace air/hydraulic manifold
(para 19-4).
(9)
If 2,500-4,000 psi (17,238-27,580 kPa) is
present, replace hydraulic hose 514
(para 19-11).
(10)
Disconnect STE/ICE-R from hydraulic hose
514 and port T1.
(11)
Connect hydraulic hose 514 to port T1.