TM-9-2320-365-20-2

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 2 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-2 - Page 1036 of 1432

KNOWN INFO
TEST OPTIONS
YES
REASON FOR QUESTION
Pressure Test or
STE/ICE-R Test #51
NO
If 2,500-4,000 psi (17,238-
27,580 kPa) is present,
suspension release tee
fitting is faulty.
7.
Go to step 8
of this fault.
Other hydraulic manifold
functions OK.
Hydraulic hoses free from
leaks.
Hydraulic hoses 508 and 510
OK.
Suspension compression tee
fitting OK.
Air/hydraulic manifold OK.
Hydraulic hose 512 OK.
Hydraulic hose 513 OK.
POSSIBLE PROBLEMS
Faulty suspension release tee
fitting.
Faulty suspension cylinder(s).
Faulty hydraulic hose(s) 509
and/or 511.
Is 2,500-4,000 psi
(17,238-27,580 kPa)
present at suspension
release tee fitting
input ports?
Replace suspension
release tee fitting
(para 19-11).
TM 9-2320-365-20-2
2-1970.12
Change 1
t2. SUSPENSION DOES NOT COMPRESS AND/OR RETURN TO NORMAL (CONT)


Back to Top