  TM-9-2320-365-20-2 - Page 115 of 1432

TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1169
2-1169
2-1169
2-1169
2-1169
CONTINUITY TEST
(1)
Remove screw and cover from 110 vac outlet
J235.
(2)
Set multimeter to ohms.
(3)
Connect positive (+) probe of multimeter to
supply pole of 110 vac receptacle J235.
(4)
Connect negative (-) probe of multimeter to
supply socket of 110 vac receptacle J235 and
note reading on multimeter.
(5)
Connect positive (+) probe of multimeter to
neutral pole of 110 vac receptacle J235.
(6)
Connect negative (-) probe of multimeter to
neutral socket of 110 vac receptacle J235 and
note reading on multimeter.
(7)
Connect positive (+) probe of multimeter to
ground pole of 110 vac receptacle J235.
(8)
Connect negative (-) probe of multimeter to
ground socket of 110 vac receptacle J235 and
note reading on multimeter.
(9)
If continuity is not present in steps (4), (6), and
(8), replace 110 vac receptacle J235
(para 16-53).