CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
TM 9-2320-365-20-2
Change 1
2-1482.29
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter to
connector J116 socket E1.
(3)
Connect negative (-) probe of multimeter to
connector J116 socket E2 and note reading
on multimeter.
(4)
If continuity is not present, go to step
14 of this fault.