SOAPY WATER LEAK TEST
(1)
Select RUN FLAT at CTIS ECU
(TM 9-2320-365-10) and listen for
obvious air escape in CTIS system.
(2)
If obvious air escape is heard,
perform repair at damaged area.
If no obvious air escape is heard,
proceed to quick release valve
leak check.
(3)
Apply soapy water solution to quick
release valve fittings at rear axle.
(4)
Check for bubbles indicating leaks.