TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
TM 9-2320-365-20-2
2-1144
2-1144
2-1144
2-1144
2-1144
TEST OPTIONS
REASON FOR QUESTION
KNOWN INFO
Continuity Test or
STE/ICE-R #91
6.
POSSIBLE PROBLEMS
Lighting fixtures DS80
and DS81 OK.
Lighting fixture DS83 OK.
Wire 706B OK.
Wire 1499K OK.
Faulty wire 3085AJ.
Faulty lighting fixture
DS82.
Is continuity present on
wire 3085B from 110/208
VAC POWER
DISTRIBUTION PANEL
to wire 3085AJ in lighting
fixture DS82?
YES
NO
If continuity is not present,
wire 3085AJ is faulty. If
continuity is present,
lighting fixture DS82 is
faulty.
Repair or replace wire 3085AJ
from lighting fixture DS83 to
DS82 (para 2-40).
Replace lighting fixture DS82
(para 16-59).
e104.
M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)
e104.
M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)
e104.
M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)
e104.
M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)
e104.
M1079 LIGHTING FIXTURE(S) DS82 AND/OR DS83 DO NOT OPERATE (CONT)