TM 9-2320-365-20-3
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(10) Apply antiseize compound to threads of radiator
draincock (14).
(11) Install radiator draincock (14) in radiator (3).
(12) Loosen two screws (15) in clamps (16) as far as possible
without disengaging screws from D-nuts (17).
(13) Unhook clamp tabs (18) from tab windows (19).
CAUTION
• Clamp tongue must be started in clamp groove.
Failure to comply may result in damage to
equipment.
• Position clamps so that screws will be toward
center of vehicle and angled down.
(14) Position two clamps (16) on lower coolant hose (20).
Change 1