TM-9-2320-365-20-3

M1078 SERIES, 2 1/2-TON, 4 X 4, LIGHT MEDIUM TACTICAL VEHICLES (LMTV)

TECHNICAL MANUAL; MAINTENANCE INSTRUCTIONS; UNIT MAINTENANCE; VOLUME NO. 3 OF 5

FEBRUARY 2006
CHANGE 3

  TM-9-2320-365-20-3 - Page 606 of 1268

TM 9-2320-365-20-3
7-82. START AND CHARGING CABLE ASSEMBLY REPLACEMENT (CONT)
(16) Install terminal lugs TL33 (23) and TL23 (24) on auxiliary
starter solenoid (20) with two lockwashers (25) and nuts
(26).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(17) Apply adhesive to nuts (22 and 26).
NOTE
Perform steps (18) and (19) on vehicles
equipped with 200 amp alternator.
(18) Install terminal lug TL36 (27) on 200 amp terminal block
terminal (28) with washer (29), lockwasher (30), and nut
(31).
(19) Tighten nut (31) to 16-18 lb-ft (21-25 N m).
7-352