b.
Installation.
(1) Apply adhesive compound to bottom threads of two
air pressure transmitters (1).
(2) Install two adapters (2) on air pressure transmitters
(1).
(3) Apply antiseize compound to threads of 90-degree
fitting (3), two tee fittings (4), and 90-degree fittings
(5).
(4) Install 90-degree fitting (1) in park control two-way
check valve (6).
(5) Install two tee fittings (4) in park control two-way
check valve (6).
(6)
Install two 90-degree fittings (5) in tee fittings (4).
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing.
Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
Failure to comply may result in injury to
personnel.