PERSONNEL HEATER REPLACEMENT/REPAIR (CONT)
(19) Position clamp (23) on heater outlet hose (2).
(20) Position clamp (23) on heater inlet hose (3).
(21) Position heater outlet hose (2) on return fitting (27).
(22) Position heater inlet hose (3) on supply fitting (28).
(23) Engage as many clamp tabs (25) as possible in tab
windows (26) allowing little or no play between
clamps (23) and heater outlet hose (2) and heater
inlet hose (3).
(24) Tighten two clamps (23) to 8-9 lb-in. (0.9-1 N•m).
(25) Measure gap between ends of two clamps (23).
CAUTION
Ensure clamp tongue is started in clamp
groove.
Failure to comply may result in
damage to equipment.
NOTE
Heater outlet hose is marked with an arrow
pointing down.
NOTE
Heater inlet hose is marked with an arrow
pointing up.
NOTE
Minimum allowable gap between ends of
clamp is 0.1 in. (0.3 cm).
If gap is less than
0.1 in. (0.3 cm), remove and re-install
clamp.