TM 9-2320-365-20-5
20-57. 200 AMP VOLTAGE REGULATOR REPLACEMENT (CONT)
(5) Disconnect
voltage
regulator
connector
(11)
from
alternator (12).
(6) Remove two screws (13), lockwashers (14), washers
(15) and voltage regulator (16) from alternator (12).
Discard lockwashers.
b. Installation
WARNING
Adhesives, solvents, and sealing com-
pounds can burn easily, can give off
harmful vapors, and are harmful to skin
and clothing. Keep away from open fire
and use in a well-ventilated area.
If
adhesive, solvent, or sealing compound
gets
on
skin
or
clothing,
wash
immediately with soap and water. Failure
to
comply
may
result
in
injury
to
personnel.
(1) Apply sealing compound to threads of two screws (1).
(2) Position voltage regulator (2) on alternator (3) with two
washers (4), lockwashers (5), and screws (1).
(3) Tighten two screws (1) to 75 lb-in. (8 N·m).
(4) Connect voltage regulator connector (6) to alternator (3).
20-356