Change 1
2-83
TM 9-2320-365-34-1
CONTINUITY TEST
(1)
Remove control valve module (para 7-10).
(2)
Remove four screws and cover from
control valve module.
(3)
Disconnect internal wiring harness
connector TSS from turbine speed sensor.
(4)
Set multimeter to ohms.
(5)
Connect positive (+) probe of multimeter
to internal wiring harness 31-pin connector
pin V.
(6)
Connect negative (-) probe of multimeter
to internal wiring harness connector TSS
pin A and note reading on multimeter.
(7)
If continuity is not present, replace
transmission internal wiring harness
(para 7-13).
(8)
Connect positive (+) probe of multimeter
to internal wiring harness 31-pin connector
pin V.
(9)
Connect negative (-) probe of multimeter
to ground and note reading on multimeter.
(10)
If continuity is present, transmission
internal wiring harness is shorted; replace
transmission internal wiring harness
(para 7-13).
CAUTION
Use care when disconnecting wiring harness
connectors. Failure to comply may result
in damage to equipment.