Change 1
2-101
TM 9-2320-365-34-1
RESISTANCE TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to pin 1 of turbine speed sensor.
(3)
Connect negative (-) probe of multimeter
to pin 2 of turbine speed sensor and note
reading on multimeter.
(4)
If resistance is less than 200 ohms or
greater than 400 ohms, replace
transmission turbine speed sensor
(para 6-5).
(5)
If resistance is between 200 and
400 ohms, replace WTEC II TEPSS
(TM 9-2320-365-20-3).
(6)
Connect internal wiring harness connector
TSS to turbine speed sensor.
(7)
Install cover on control valve module with
four screws.
(8)
Install control valve module (para 7-10).
(9)
Connect adapter cable 24-pin connector to
internal wiring harness 24-pin connector.
(10)
Tighten screw in adapter cable 24-pin
connector.
(11)
Connect batteries (TM 9-2320-365-20-3).