TM 9-2320-365-34-2
21-10
Change 2
All data on pages 21-11 and 21-12,
including pages 21-11 and 21-12 deleted.
21-2.
TRANSMISSION REPAIR (CONT)
(16) Tighten three bolts (14 and 15) to 66-81 lb-ft (90-
110 N•m).
(17) Tighten 15 bolts (13) to 40-42 lb-ft (54-57 N•m).
(18) Position main housing (1) horizontal with ground.
(19) Install rotating clutch (18) in main housing (1).
(20) Position front support pump (19) on main housing (1)
with five bolts (20) and six bolts (21).
(21) Tighten five bolts (20) and six bolts (21) to 42-50 lb-ft
(57-68 N•m).
(22) Position gasket (22) and torque converter housing
(23) on main housing (1) with 20 bolts (24).
(23) Tighten 20 bolts (24) to 42-50 lb-ft (57-68 N•m).
WARNING
NOTE
Step (19) requires the aid of an assistant.
Torque converter housing weighs appro-
ximately 65 lbs (30 kgs).
Attach a suitable
lifting device prior to installation.
Failure
to comply may result in injury to
personnel or damage to equipment.
NOTE
Step (22) requires the aid of an assistant.