TM 9-2320-366-10-2
Table 3-2. Troubleshooting (Cont)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
e1. ENGINE DOES NOT CRANK (CONT).
(c)
Attempt to start engine (para 2-27a or b).
(d)
If engine still does not crank, check circuit breakers (CB21 and CB77) to see if either is tripped.
If either circuit breaker (CB21 and CB77) is tripped or engine does not crank, notify Unit
Maintenance.
(e)
Install PDP cover (para 3-17b).
(f)
Position master power switch to off (para 2-27f).
e2. 12 VDC AND 24 VDC CIRCUITS DO NOT OPERATE
Step 1. Check circuit breaker (CB70) in Power Distribution Panel (PDP) to see if it is tripped.
(a)
Position main light switch to SER DRIVE (para 2-27c).
(b)
Check circuit breaker (CB70) to see if it is tripped.
If circuit breaker (CB70) is tripped, push in to reset.
Step 2. Check to see if service lights illuminate.
(a)
Position main light switch to SER DRIVE (para 2-27c).
If service lights do not illuminate, Notify Unit Maintenance.
(b)
Position main light switch to OFF (para 2-27c).
(c)
Install PDP cover (para 3-17b).
e3. 24 VDC CIRCUITS DO NOT OPERATE
NOTE
Perform a1. ENGINE DOES NOT CRANK, prior to beginning this task.
Notify Unit Maintenance.
e4. DELETED
e5. ENGINE CRANKS BUT DOES NOT START
NOTE
Perform Engine System Troubleshooting task a2. Engine Cranks But Does Not Start before performing
this task.
Notify Unit Maintenance.
Change 1
3-33