INITIAL SETUP
Equipment Conditions
Engine shut down (TM 9-2320-366-10-1).
References
TM 9-4910-571-12&P
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
e1.
CIRCUIT BREAKER DOES NOT OPERATE
KNOWN INFO
TEST OPTIONS
REASON FOR QUESTION
Nothing.
POSSIBLE PROBLEMS
Faulty circuit breaker.
Continuity Test or
STE/ICE-R Test #91
1.
WARNING
Read WARNING
on following page.
START
Replace circuit breaker (para 7-9).
YES
NO
Circuit breaker is OK.
Return to
troubleshooting for affected circuit.
If continuity is not present,
circuit breaker is faulty.
TM 9-2320-366-20-1
Is continuity present
through circuit breaker
(refer to Table 2-8.
Function To Circuit Breaker
Cross Reference or Table
2-8.1.
Circuit Breaker to
Function Cross Reference)?
2-158
Change 1