CAUTION
Use care when testing electrical connectors.
Do not damage connector pins or sockets
with multimeter probes.
Failure to comply
may result in damage to equipment.
NOTE
Inspect connector pins/sockets for damage,
corrosion, and serviceability.
Check that
connector pins are not pushed back and
are capable of making good contact.
CONTINUITY TEST
TM 9-2320-366-20-1
Change 1
2-393
(1)
Remove PDP cover (TM 9-2320-366-10-2).
(2)
Remove circuit breaker CB70 from PDP.
(3)
Remove instrument panel assembly for
access (para 7-15).
(4)
Disconnect connector PX15 from main
light switch connector.
(5)
Position main light switch main selector
lever to SER DRIVE (TM 9-2320-366-10
-1).
(6)
Position main light switch auxiliary selector
lever to PNL BRT (TM 9-2320-366-10-1).
(7)
Set multimeter to ohms.
(8)
Connect positive (+) probe of multimeter
to main light switch connector pin F.
(9)
Connect negative (-) probe of multimeter to
main light switch connector pin B and note
reading on multimeter.
(10)
If continuity is not present, replace main
light switch (para 7-17).
(11)
Position main light switch auxiliary lever to
OFF (TM 9-2320-366-10-1).
(12)
Position main light switch main selector
lever to OFF (TM 9-2320-366-10-1).