(10)
Position dust boot on terminal lug TL35.
CONTINUITY TEST
(1)
Set multimeter to ohms.
(2)
Connect positive (+) probe of multimeter
to relay K11 socket 87A on PDP.
(3)
Raise cab (TM 9-2320-366-10-1).
(4)
Lift dust boot on terminal lug TL35.
(5)
Remove self-locking nut, washer, and
terminal lug TL35 from voltage regulator.
Discard self-locking nut.
(6)
Connect negative (-) probe of multimeter to
terminal lug TL35 and note reading on
multimeter.
(7)
If continuity is not present, go to step 9
of this fault.
(8)
Position terminal lug TL35 on voltage
regulator with washer and self-locking nut.
(9)
Tighten self-locking nut to 23-27 lb-in.
(3 N.m).