TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
TM 9-2320-366-20-2
2-1102
2-1102
2-1102
2-1102
2-1102
1.
START
YES
NO
Circuit breaker OK.
Is 24 vdc present at
connector PX34-1?
This question eliminates
possible problems and
determines where
troubleshooting continues.
KNOWN INFO
POSSIBLE PROBLEMS
WARNING
Read WARNING
on following page.
TEST OPTIONS
Voltage Test or
STE/ICE-R #89
REASON FOR QUESTION
INITIAL SETUP
Equipment Condition
Engine shut down (TM 9-2320-366-10-1).
Personnel Required
(2)
Tools and Special Tools
Tool Kit, Genl Mech (Item 46, Appendix C)
STE/ICE-R (Item 41, Appendix C)
Multimeter, Digital (Item 22, Appendix C)
References
TM 9-4910-571-12&P
Go to step 4 of this fault.
e96.
ENGINE FAN DOES NOT TURN OFF USING RADIATOR FAN OFF SWITCH
Faulty dashboard cable
assembly.
Faulty fan solenoid.
Faulty fan clutch.
Faulty radiator fan off
switch.