KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
4.
POSSIBLE PROBLEMS
Other crane functions from
remote station OK.
Telescope in solenoid
cable OK.
Telescope in solenoid OK.
External remote control
cable OK.
Remote control cable OK.
Faulty remote control
box internal wiring
harness.
Faulty telescope in/out
controller.
If continuity is not present,
remote control box internal
wiring harness is faulty.
If continuity is present,
TELESCOPE IN/OUT
controller is faulty.
Is continuity present
from remote control box
connector pin D to
TELESCOPE IN/OUT
controller internal wiring
harness connector pin 3
and from remote control
box connector pin H to
TELESCOPE IN/OUT
controller internal wiring
harness pin 1?
NO
YES
Repair remote control box
internal wiring harness
(para 7-32).
Replace TELESCOPE IN/OUT
controller (para 7-32).
e126.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE
e126.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE
e126.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE
e126.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE
e126.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE IN DOES NOT OPERATE FROM REMOTE
STATION (CONT)
STATION (CONT)
STATION (CONT)
STATION (CONT)
STATION (CONT)


Back to Top