KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
4.
POSSIBLE PROBLEMS
Faulty remote control
box internal wiring
harness.
Faulty telescope in/out
controller.
If continuity is not present,
remote control box internal
wiring harness is faulty.
If continuity is present,
TELESCOPE IN/OUT
controller is faulty.
Other crane functions from
remote station OK.
Telescope out solenoid
cable OK.
Telescope out solenoid OK.
External remote control
cable OK.
Remote control cable OK.
Is continuity present
from remote control box
connector pin C to
TELESCOPE IN/OUT
controller internal wiring
harness pin 4 and from
remote control box
connector pin H to
TELESCOPE IN/OUT
controller internal wiring
harness pin 1?
YES
NO
Repair remote control box
internal wiring harness
(para 7-32).
Replace TELESCOPE IN/OUT
controller (para 7-32).
e127.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE
e127.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE
e127.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE
e127.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE
e127.
M1089 MATERIAL HANDLING CRANE (MHC) TELESCOPE OUT DOES NOT OPERATE FROM REMOTE
STATION (CONT)
STATION (CONT)
STATION (CONT)
STATION (CONT)
STATION (CONT)