KNOWN INFO
TEST OPTIONS
Continuity Test or
STE/ICE Test #91
REASON FOR QUESTION
4.
POSSIBLE PROBLEMS
Faulty remote control
box internal wiring
harness.
Faulty SWING CW/CCW
controller.
If continuity is not present,
remote control box internal
wiring harness is faulty.
If continuity is present,
SWING CW/CCW
controller is faulty.
Other crane functions from
remote station OK.
Swing CCW solenoid
cable OK.
Swing CCW solenoid OK.
External remote control
cable OK.
Remote control cable OK.
Is continuity present
from remote control box
connector pin A to
SWING CW/CCW
controller internal wiring
harness pin 3 and from
remote control box
connector pin H to
SWING CW/CCW
controller internal wiring
harness pin 1?
YES
NO
Repair remote control box
internal wiring harness
(para 7-32).
Replace SWING CW/CCW
controller (para 7-32).
e129.
M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM REMOTE
e129.
M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM REMOTE
e129.
M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM REMOTE
e129.
M1089 MATERIAL HANDLING CRANE (MHC) SWING CCW DOES NOT OPERATE FROM REMOTE